Chillers
Start, stop and sequence chillers to the load, and monitor chilled water supply and return temperatures and faults.
Chillers · SequencingOne building, one system that sees all of it. We bring HVAC, water, lighting, power and third-party systems, whatever their manufacturer, onto a single control platform: clear screens, instant alarms and operating records that give you the full picture of your building at any moment.
Free consultation and free site visit in Riyadh
Start, stop and sequence chillers to the load, and monitor chilled water supply and return temperatures and faults.
Chillers · SequencingRun pumps in rotation to share running hours, and control their speed to hold the required pressure.
Pumps · VFD · Duty / StandbyMonitor roof and ground tank levels, run the transfer pumps, and alarm on low level or overflow.
Water Tanks · Level ControlRun to schedule, hold the set temperature, and monitor compressor status and faults.
Package UnitsControl supply air temperature, fresh air dampers and fan speed, and monitor filter condition.
AHU · FAHURun heaters to schedule and set temperature, and monitor their status and faults.
HeatersOn/off switching, dimming, and time schedules for each zone based on working hours.
Lighting · On/Off · Dimming · SchedulesRun toilet, kitchen and car park fans to schedule or to air quality readings.
Exhaust & Ventilation FansMonitor generator status and fuel level, breaker status, and energy meter readings.
Generators · LV Panels · Meters| System | Equipment | Connection |
|---|---|---|
| UPS | Eaton 93PS UPS | BACnet/IP |
| Precision cooling | Montair CRAC units, MCX controllers | Modbus RTU |
| Energy meters | Schneider PM5340 / PM2120 power meters | Modbus RTU (RS-485) |
| Water leak detection | TTK FG-NET leak detection | Modbus TCP |
| Aspirating smoke detection | ModuLaser aspirating smoke detectors | Modbus TCP |
| Isolation transformers | Isolation transformers, thermal protection contacts | Modbus + Dry contacts |
| Fan coil units | FCUs via the AC central controller | BACnet/IP |
| Water and BTU meters | Water and BTU meters | Gateway |
Yes, and that is the core of this service. Most modern equipment supports open communication protocols, and what does not is connected through gateways or dry contacts. The result is one screen for the whole building instead of a separate panel for every system.
In most cases, yes. Send us the model and its communication document, and before any work starts we confirm what can be read and controlled, so you know the outcome in advance.
The cause is usually in the communication settings rather than the device itself, such as address numbering or data format. We check these details point by point and match every reading against the device display before handover.
Yes. Each system gets its own graphics page, prioritised alarms that reach the on-call person by phone call, SMS, WhatsApp or email, and trend logs for review.
No. We start with read-only data, and no control commands are enabled until they are agreed and tested with your team present.
Send us the drawings or the IO list, or call us directly. We review your project and reply with a clear quotation or the questions we need answered.